Beam-steering loudspeakers
SC-90SL
Slim-line 90-channel column — full control from 350 Hz, 147 mm deep.
The largest slim column — 90 individually amplified transducers in a line 1,720 mm tall and only 147 mm deep, with vertical control from 350 Hz for long throws in rooms where a standard column cannot project from the wall.
- 90 channels and four beams in a cabinet only 147 mm deep
- Vertical control from 350 Hz for long throws and reverberant rooms
- The slim format of the SC-90, on the same U-bracket family


Specifications
SC-90SL at a glance
Values from the current EDC datasheet, with EDC's September 2026 confirmations applied. Notes explain anything a downloadable document states differently.
| Acoustic | |
| Frequency range | 80 Hz – 20 kHz (±3 dB) |
|---|---|
| SPL | 104 dB at 10 m (1 element), configuration dependentLong-term peak, dB Leq (linear). See the measurement note on the range page. |
| Coverage control | 1° – 120° horizontal and vertical |
| Pan / tilt | ±60° in 0.1° steps |
| Beams | 4, independently shaped |
| Vertical control from | 350 Hz |
| Horizontal control from | 3 kHz |
| Off-axis rejection | 20 dB |
| Transducers & amplification | |
| HF drivers | 81 × 1" soft dome, each on its own 30 W amplifier |
| LF / mid drivers | 9 × 5", each individually powered (200 W) |
| DSP channels | 90 |
| Processing | |
| User DSP | HPF/LPF to 48 dB/oct · 8-band EQ · compressor · limiter · delay to 100 m · FIR 2,048 taps |
| Connectivity | |
| Audio | 1 × XLR3 line in, 1 × XLR3 line out; optional AES3 stereo or RJ45 Dante input |
| Network audio | 2 channels over Dante or AES67, assignable to any of the four beams |
| Control | RJ45 Ethernet 10/100 — a separate port from Dante by default |
| Power | |
| Mains draw | 600 W / 2.5 A (music), powerCON TRUE1, 110 – 255 V AC |
| Physical | |
| Dimensions (W × H × D) | 142 × 1720 × 147 mm |
| Weight | 40 kg |
| Construction | ½" birch plywood |
| Rigging | 8 × M10; slim U-bracket |
| Environment | |
| Enclosure protection | IP55 standard; IP65 with the weatherised optionour own rating; the enclosure is not third-party tested to IEC 60529. |
| Operating temperature | −20 °C to +50 °C |
| Options | |
| Weatherised · Monitored · Dante/AES · 24 V DC | Available |
The SC-90SL carries the SC-90’s ninety channels in the slim format: 81 high-frequency and 9 mid-range drivers, each with its own amplifier and processing channel, in a cabinet 1,720 mm tall and 147 mm deep. It is the model to specify when a room needs vertical control from 350 Hz but the architecture will not accept a 330 mm-deep column — a narrow pilaster, a heritage wall, a flush position beside a screen.
A note on the name. SL is a variant suffix on the column series, not a separate range: the slim models are the SC-30SL, SC-60SL and SC-90SL. Earlier marketing material called them the SL-30, SL-60 and SL-90; the datasheets and this site use the suffix form.
Downloads
Documents for the SC-90SL
- 3d-pdf 3D PDF model — SC-90SL (slim column) 3.5 MB
- ae-spec Architects & Engineers specifications (v2) — editable Word document v2 · 2026-09 · 51 KB
- ae-spec Architects & Engineers specifications (v2) — PDF v2 · 2026-09 · 96 KB
- cad Revit families and DWG — our position we do not publish native Revit families or DWG. The STEP solids are the manufacturer's own models and import directly into Revit, Inventor, SolidWorks, Rhino and AutoCAD, which covers most coordination work. If a project needs a Revit family or a DWG for a specific model, ask us and it will be produced for that project rather than guessed at from a generic block.
- compliance Voice-alarm and conformity position — our position A monitored version of every model is built for EN 60849 voice-alarm systems, but the loudspeakers are not separately certified — voice-alarm approval is granted to the installed system, not to a component, so there is no product certificate to publish. Bring the certifying body in at design stage and we will supply the technical data the system certification needs.
- datasheet Slim column series specifications — SC-30SL, SC-60SL, SC-90SL (v5) v5 · 2024-10 · 828 KB
- gll EASE data — exported per configuration from the EDC Pro app — our position We do not publish a fixed GLL library. A software-defined cabinet has an effectively unlimited number of dispersion patterns, so a handful of pre-baked ones would not describe the system you are designing. Design the coverage in the Pro app and export 3D balloon data per beam and per array for EASE. Ask us if you need an export before you have the app.
- manual EDC Speakers Network API — control protocol specification 2019-12 · 2019-12 · 336 KB
- rigging Slimline column series U-brackets 2024-04 · 481 KB
- cad STEP model — SC-90SL — on request On request. Talk to us before you model the SC-90SL and we will confirm the cabinet dimensions for the revision you are specifying, then send the matching file.
- cad STEP model — SC-90SL mounting bracket 2026-09 · 92 KB
- warranty Limited product warranty (September 2026) 2026-09 · 2026-09 · 166 KB
Questions about the S-Series
What is the frequency range?
How loud are they?
Can they be used outdoors?
Do they take Dante or AES3 digital audio?
How are they mounted?
Can the system report faults?
Next step
Hear what happens when nothing else interferes.
An EDC session is a technical evaluation of sound behaviour, not a sales demonstration. See reflections reduced, coverage stabilised and spatial accuracy preserved — modelled first, then measured.